TwinFlo 100e Downflow Brining Service Manual

This manual describes the TwinFlo100e downflow brine treatment system’s control valve data, timer programming, assembly, installation and start-up.


TwinFlo 100e Downflow Brining Service Manual - cover page
Brand
TwinFlo
Document type
Service Manual
Language
English
Pages
36
File format
PDF
File size
2.3 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
1912D309B711911E2259297246007BBC

About this manual

This service manual provides detailed instructions for installing, programming, and maintaining the TwinFlo 100e downflow brining system. It includes electrical specifications, timer programming methods, assembly diagrams, and troubleshooting guides. The manual also covers valve components, meter settings, and regeneration cycles for water softening applications.

The TwinFlo 100e is designed for downflow regeneration and is factory preset for immediate regeneration. Users can adjust settings for equipment size, salt dosage, and regeneration timing. It supports both US and metric units and includes safety and operational guidelines for proper installation and maintenance.

What's inside

  • CONTROL VALVE DATA
  • TIMER PROGRAMMING
  • ASSEMBLY
  • INSTALLATION AND START-UP
  • TROUBLE SHOOTING
  • SERVICE ASSEMBLIES

Specifications

Electrical Specifications220 or 110 volts, 50/60 Hz, using a plug-in transformer to reduce it to 24 volts
Temperature Limits34 - 110° F or 1 - 38 ° C
Water Pressure Range20 - 125 psi or 1.4 - 8.8 Kgf/sq. cm.
Regeneration TypeUpflow or Downflow
Valve Base Thread2-1/2″, 8 NPSM
Riser Pipe Diameter1.05″ Outside Diameter
Service Cv3.8
Backwash Cv0.8

Frequently asked questions

How do I program the TwinFlo 100e timer?

Push and hold the UP and DOWN arrows simultaneously until the program light indicator comes on. Set the time of day to 12:01 P.M. for US or 12:01 for metric. Use the UP/DOWN arrows to adjust settings and depress the Extra Cycle Button to proceed.

What is the regeneration type for TwinFlo 100e?

The TwinFlo 100e is factory preset for immediate regeneration (7-2) and regenerates with soft water.

How do I calculate the water meter setting?

Subtract the regeneration water volume from the equipment capacity. For example, with 900 gallons capacity and 49.0 gallons regeneration water, set the meter at 851.0 gallons.

What are the electrical requirements for TwinFlo 100e?

It operates on 220 or 110 volts, 50/60 Hz, and requires a plug-in transformer to reduce voltage to 24 volts.