This manual is intended to help you use the ProFloSXT Water Saving Valve.
This service manual provides detailed instructions for installing, starting up, and operating the ProFloSXT water-saving valve. It includes guidelines for plumbing and electrical setup, safety precautions, and timer programming. The manual also covers regeneration cycles, flow control, and troubleshooting tips for maintaining proper function.
The valve is designed for potable water systems and must be installed by a plumbing professional. It requires a minimum of 20 psi water pressure and an uninterrupted AC power supply. Temperature and pressure limits are specified to prevent damage. The manual includes job specification sheets and detailed step-by-step procedures for setup and maintenance.
| Water Pressure Requirement | Minimum 20 psi |
|---|---|
| Maximum Water Pressure | 125 psi |
| Maximum Water Temperature | 110°F (43°C) |
| Power Backup | 48 hours minimum |
A minimum of 20 psi water pressure is required for regeneration valve to operate effectively.
Water temperature must not exceed 110°F (43°C).
The power backup lasts a minimum of 48 hours.
Press and hold the Extra Cycle button for five seconds.