Model 5600SE Downflow service manual
This document serves as a service manual for the Kinetico Model 5600SE Downflow water softener. It provides detailed instructions for installation verification, including plumbing requirements and electrical safety. The guide outlines specific procedures for valve installation, start-up, and control programming, explaining how to set time of day, treated water capacity, and regeneration schedules.
| Minimum Water Pressure | 25 lbs |
|---|---|
| Maximum Water Pressure | 120 psi |
| Maximum Water Temperature | 110°F |
| Minimum Drain Pipe Size | 1/2" |
| Recommended Drain Line Size | 3/4" |
Push and hold the Extra Regeneration button for 5 seconds to start an Extra Regeneration immediately.
A minimum of 25 lbs of water pressure is required for regeneration valve to operate effectively.
Do not exceed 120 psi water pressure.
Regeneration every 7 days minimum.