This manual provides maintenance information on the Model 2750 Downflow & Upflow water softener.
This manual provides service instructions for the Koch Model 2750 water softener, applicable to both downflow and upflow configurations. It details pre-installation checks, including requirements for water pressure (minimum 25 psi, maximum 120 psi) and electrical supply (115 volt, 60 Hertz).
| Minimum Water Pressure | 25 pounds |
|---|---|
| Maximum Water Pressure | 120 p.s.i. |
| Maximum Water Temperature | 100° F |
| Electrical Supply | 115 volt, 60 Hertz |
A minimum of 25 pounds of water pressure is required for the regeneration valve to operate effectively.
Turn the manual regeneration knob clockwise to engage the program wheel and start the regeneration program.
The backwash time is determined by the number of pins in the backwash section of the program wheel, where the number of pins times two equals the time in minutes.