The 403-1 System is an automation educational system that includes the functions of distributing, joining, and sorting
This manual provides operating instructions for the Festo Didactic 403-1 System, which includes distributing, joining, and sorting stations. It covers safety guidelines, mechanical, electrical, and pneumatic setup, commissioning steps, maintenance, and technical data. The document is multilingual and intended for educational use in supervised environments.
The system requires compliance with national electrical regulations, supervised operation, emergency-off devices, and protection via residual current devices. It includes detailed terminal assignments and networking instructions for each station.
An emergency-off device must be provided, with at least one inside and one outside.
Type-B residual current devices with a residual current of ≤ 30 mA must be used.
A supervisor, who is a qualified electrician or trained in electrical engineering, must oversee it.