This manual introduces the basic functions and usage methods of Fastech Position Table (PT).
This document serves as a user guide for the Position Table feature of the Ezi-SERVO Plus-R servo drive. It details how to access the Position Table window, manage data loading and saving, and utilize various operational modes such as Normal and Single Step execution. The guide also covers teaching functions and signal-based control.
| Maximum Position Table Steps (Ezi-SERVO-PR) | 256 steps |
|---|---|
| Maximum Position Table Steps (Ezi-SERVO-PR-MI) | 64 steps |
| Acceleration Time Range | 1 to 9,999 ms |
| Deceleration Time Range | 1 to 9,999 ms |
Up to 256 steps can be saved for the Ezi-SERVO-PR model.
You can save the data to the drive's ROM area or to an external file.
The two modes are Normal, which executes all commands in order, and Single Step, which executes only a single command.