This document details the general installation procedures for epoxy grouts manufactured by The Euclid Chemical Company.
This guide provides detailed installation procedures for Euclid Chemical Company's epoxy grouts, including E3-FLOWABLE, E3-DEEP POUR, and E3-XTREME. It covers surface and form preparation, mixing protocols, placement techniques, and curing. Temperature control is critical for proper performance. The guide also includes safety precautions and warranty information.
The document emphasizes mechanical preparation of surfaces, proper mixing without additives, and temperature management to ensure optimal flow and curing. It advises using head boxes for machinery grouting and warns against vibrating the grout. Warranty details and safety precautions are included for compliance and liability protection.
Grouts work best at 50°F to 90°F (10°C to 32°C).
DO NOT ADD WATER, SOLVENT OR ANY OTHER CHEMICALS TO THE PRODUCT!
The warranty is one (1) year from the date of purchase.