Design Manual introduces the design method of carbon fiber grid strap composite system for strengthening masonry structures.
This document serves as a design manual for the Fortress Carbon Grid Strap FRP composite system, intended for strengthening masonry walls in flexural (out-of-plane) applications. It provides the necessary procedures to satisfy the design requirements of ICC-ES Acceptance Criteria AC 125. The manual outlines the system's description, installation instructions, substrate preparation guidelines, and specific design properties for engineering calculations.
| Storage life | 10 years |
|---|---|
| Adhesive storage life | two years |
| Ultimate Tensile Strength | 1,960 MPa (284.2 ksi) |
| Tensile Modulus | 118.2 GPa (17.16 Msi) |
| Guaranteed Tensile Strength | 1,618 MPa (234.7 ksi) |
| Guaranteed Ultimate Strain | 0.0129 mm/mm (0.0129 in./in.) |
| Nominal FRP thickness | 0.697 mm2/mm (0.0274 in.2/in.) |
The objective is to satisfy the design requirements for ESR No. 3815 regarding the use of the Fortress Carbon Grid Strap FRP composite system for strengthening masonry walls.
Room and surface temperatures must be between 13 ºC and 38ºC (55 ºF to 100 ºF) during installation.
The mixing ratio is 2:1 by volume (100:35 by weight) for components A and B.