IETG FlowHawk 8000-FHK Flow Monitor Installation Operation and Maintenance Manual

This manual is about IETG FlowHawk product installation, operation and maintenance instructions


IETG FlowHawk 8000-FHK Flow Monitor Installation Operation and Maintenance Manual - cover page
Brand
IETG
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
399
File format
PDF
File size
6.7 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
C0AECFB22F6249EC160EB623976FF578

About this manual

The IETG FlowHawk flow monitor measures open channel flow in sanitary sewers, storm sewers, and combined sewers to assist with planning, infiltration monitoring, and overflow detection. The device is powered by ADS and features exceptional accuracy in measuring flow depth and velocity.

What's inside

  • Introduction
  • System Overview
  • Sensor Installation
  • Communication
  • Configuration and Activation
  • Monitor Installation
  • Maintenance and Troubleshooting
  • Specifications

Specifications

Operating Temperature-20° to 60° C (-4° to 140° F)
Enclosure Dimensions451 mm long by 222 mm maximum diameter
Weight13.7 kilograms (30.3 lbs)
Power SourceOne 12-volt IS alkaline battery pack

Frequently asked questions

What environments is the FlowHawk monitor certified for?

The FlowHawk flow monitor is certified for use in all classified hazardous sanitary sewer and industrial hazardous areas.

Can the FlowHawk monitor be used with non-approved devices?

No, connection of any non-approved devices could result in unsafe operation and will immediately void the warranty and IS certification.

How many sensors can the monitor accommodate?

The monitor is approved for accommodating up to two of the same or different types of IS sensors.