About this manual

This manual provides step-by-step instructions for installing and operating England’s Stove Works, Inc. wood stoves, including models 13-NC, 50-SNC13, and 50-TNC13. It covers critical safety precautions, flue sizing, room ventilation, and fire-starting procedures. Maintenance sections detail glass care, gasket replacement, and ash disposal. The manual also includes important warnings about not connecting to air ducts or burning garbage, and emphasizes the need for proper clearances and chimney installation to prevent fire hazards.

The guide includes diagrams, parts lists, and troubleshooting tips, with contact information for customer support and technical assistance. It is designed for DIY users but recommends professional installation if unsure. Optional blower motor installation and lubrication are also covered for enhanced heat distribution.

What's inside

  • Precautionary Statements
  • Installation
  • Operation
  • Maintenance
  • Questions & Tips
  • Parts and Options
  • Warranty
  • Important Information

Frequently asked questions

Can I burn garbage or flammable fluids in this stove?

DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.

What flue size is required?

A 6” diameter flue is required for proper performance.

Can I install this stove in a mobile home?

Yes, but only with outside air hookup for pedestal models. DO NOT INSTALL IN A SLEEPING ROOM.

How do I lubricate the optional blower motor?

Use an eye dropper to drip 5-7 droplets of SAE 20 oil into the oil port on the side of the blower motor, no less than every three months.