This document is a DRUID LCD 1x electric fence energizer installer manual that provides detailed instructions on how to install, connect and configure the product.
This manual provides step-by-step instructions for installing and maintaining the Nemtek DRUID LCD 1x electric fence energizer. It covers mounting, battery replacement, PC board replacement, wiring configurations, and service indicators. The device uses a 12V 7AH rechargeable lead-acid battery and features advanced arc detection technology to maintain fence voltage despite environmental conditions. Safety and compliance guidelines for fence installation are also included.
The manual includes diagrams for fence wiring, fuse fault descriptions, and configuration jumpers. It also details how to use the remote keypad for settings and how to bypass gate alarm inputs. Installation must comply with municipal laws and international standards, with specific requirements for warning signs, grounding, and cable routing.
| Battery Type | 12V 7AH rechargeable lead-acid |
|---|---|
| Arc Detection Technology | Advanced patented system to maintain higher energy levels |
| Backup Time | Typically over 24 hours with full charge |
It uses a 12V 7AH rechargeable lead-acid battery. Non-rechargeable batteries must not be used.
It detects arcing and operates at a voltage just below the arcing threshold to maintain higher energy levels.
Typically over 24 hours, though it varies with fence condition.