This document is the user manual for NDR 1292 Automatic Energy Selector, which introduces the use, maintenance and maintenance methods of the refrigerator
This manual provides step-by-step instructions for installing, operating, and maintaining the Dometic NDR 1292 automatic energy selector refrigerator, which runs on both LP gas and electricity. It covers safety precautions, ventilation requirements, gas and electrical connections, and testing procedures. The guide also includes detailed diagrams and component labels for proper setup and troubleshooting.
Installation must comply with U.S. and Canadian codes for gas and electrical systems, including grounding, ventilation, and sealing requirements to ensure safe operation in recreational vehicles and mobile homes.
| Operating Modes | LP-Gas and Electric |
|---|---|
| Ventilation Requirement | One lower fresh air intake and one upper exhaust vent |
For 17 feet (5 meters) of wire, use 14 AWG; for 27 feet (8 meters), use 12 AWG.
No, carpeting must be removed or protected with a metal or wood panel beneath the appliance.