This is an electronic service manual for Doosan P425WCU-EX-T2, HP375WCU-EX-T2 and XP375WCU-EX-T2 compressors. It covers the compressor's operation principle, diagnostic code troubleshooting, electrical circuit troubleshooting, system schematics and wiring diagrams, electrical component locations and electrical parts list.
This electronic service manual covers the P425WCU-EX-T2, HP375WCU-EX-T2, and XP375WCU-EX-T2 compressor models. It provides general information regarding the Titan controller, which serves as the heart of the monitoring and control system, utilizing analog and digital inputs and outputs to manage package monitoring and control functions.
| Controller Type | Titan controller |
|---|---|
| Digital Input Voltage | 24 VDC, 12 VDC, or 0 VDC |
| Digital Output Voltage | 12 VDC |
| Network Protocol | J1939 CAN network |
The Titan controller is the heart of the compressor monitoring and control system, providing data collection, package monitoring, and control functions.
Temperature sensors are thermistor type devices where the resistance output changes with a corresponding temperature change.
Pressure transducers have an output signal range of 0.5 VDC to 4.5 VDC.