This manual provides detailed instructions on how to operate and maintain the 20 Gallon Smart Foam Unit.
This manual provides instructions for operating, installing, and maintaining the FI 20 Gallon Smart Foam Unit. It covers safety precautions, setup, chemical handling, and troubleshooting. The unit is designed for foam application using compressed air and pre-mixed solutions. Maintenance includes regular inspection of hoses, filters, and pump seals. Specifications include a 20-gallon capacity, 30-foot discharge hose, and compatibility with alkaline and acid chemicals.
| Capacity | 20 gallons (75.7 liters) |
|---|---|
| Discharge Hose Length | 30 ft. (9.1 m) |
| Output Volume | 20-32 gal/min (75.7-121.1 l/min) of foam |
| Air Pressure Requirement | 40-80 psi (3-5 bar) |
| Fluid Temperature Range | 40-100˚F (4.4-37˚C) |
Do not exceed an incoming air pressure of 100 psi (7 bar).
Adjust the needle valve in ¼ turn increments, allowing 30 seconds between adjustments, until desired consistency is achieved.
Pump seals are available in Santoprene (standard), Viton (V), or Kalrez (K).