This manual provides instructions on the use of Compact Weather Station devices
This manual provides instructions for installing, configuring, and operating Lufft’s compact weather stations. It includes safety guidelines, equipment descriptions, technical data, and communication protocols. The devices measure various environmental parameters including temperature, humidity, air pressure, wind, and precipitation. Each model has different sensor combinations, and the manual details setup using the UMB-Config-Tool and RS485 interface.
The manual also covers maintenance, firmware updates, and troubleshooting. Technical specifications such as power requirements, dimensions, and environmental operating conditions are provided for each model. Safety precautions and correct usage are emphasized to ensure proper operation and prevent damage or injury.
| Power Supply | 24VDC ±10% or 12VDC (with restrictions) |
|---|---|
| Current Consumption (Sensor) | WS200-UMB: 50 mA / 1.2VA (24VDC), 16.5 mA / 0.2VA (12VDC) |
| Dimensions | WS200-UMB: Ø 150mm, height 194mm |
| Weight | WS200-UMB: ca. 0.8 kg |
| Protection Class | III (SELV) |
| Protection Type | IP64 |
| Operating Temperature | -50°C to +60°C |
| Operating Humidity | 0% to 100% RH |
| RS485 Interface | 2 wire, half-duplex |
| Baud Rates | 1200, 2400, 4800, 9600, 14400, 19200, 28800, 57600 |
The device is powered by 24VDC ±10% or 12VDC (with restrictions).
The operating temperature range is -50°C to +60°C.
Configuration is done using the UMB-Config-Tool (Windows® PC software) via the RS485 interface.