This guide describes the compatibility of 600FD Flexible Draper Platforms with John Deere 70 Series STS and John Deere S-Series Combines. It introduces basic setup and troubleshooting. It also introduces calibration procedures and a sensor voltage map.
This document serves as a quick reference guide for the Deere 600FD Flexible Draper Active Header Height Control (AHHC) system. It provides essential information for operators regarding the setup and operation of the system on John Deere S-Series Combines and 70 Series STS combines. The guide details the compatibility of the 600FD platform with various combine models and outlines the specific sensor voltage requirements for proper function.
| Operating range of AHHC Sensors | 0.5 – 4.5 volts |
|---|---|
| Recommended sensor voltage setting | 0.9 – 4.1 volts |
| Minimum sensor voltage for calibration | 1.2 V |
The two modes are On-ground (flex mode) for crops like soybeans and lentils, and Off-ground (rigid mode) for crops like wheat and barley.
It is highly recommended to set the sensors at 0.9 – 4.1 volts.
Common causes include sensors out of range, damaged wiring harness, broken sensors, lock-out brackets still installed, or off-ground sensor arms pinned up.