This is a service manual for Atwood Air Conditioner products. It includes instructions on how to identify product models, troubleshooting, and repairs.
This service manual provides technicians with tools and procedures to diagnose and repair Atwood AirCommand air conditioners. It includes exploded views of ducted and non-ducted units, part identification, sequence of operation, and troubleshooting guides for error codes and typical faults. The manual also covers warranty procedures and replacement part reference charts.
The document is organized into sections covering tools, model identification, parts, sequence of operation, thermostat control, troubleshooting, and schematics. It supports both cooling and heat pump models, including non-ducted and ducted configurations, with specific part numbers and component details for each variant.
| Model Number Description | AC – 1351 W Color W - White B - Black Generation 1 - First Generation Power rating & Ducted/Non-Ducted 135 – 13.5K BTU; Non-Ducted AC (Air Conditioner) 136 – 13.5K BTU; Ducted AC (Air Conditioner) 150 – 15.0K BTU; Non-Ducted HP (Heat Pump) 151 – 15.0K BTU; Ducted HP (Heat Pump) |
|---|
Turn the power on at the circuit breaker and verify 110VAC between neutral (N) and Line (L). Press the ON/OFF button and MODE button to select FAN. Cycle through LO, MED, and HIGH fan speeds checking that all run. On HIGH speed, verify 110VAC on the HF terminal. On MED speed, verify 110VAC on the MF terminal. On LOW speed, verify 110VAC on the LF terminal.
The unit requires 110VAC between neutral and line to operate.
The compressor will start within three minutes after setting the temperature.
The output is 110VAC to the HF terminal with respect to neutral on high speed.