Digilube DL-5002HC Programmable Lubrication System Installation and Operational Manual

This document is an operating manual for the Digilube programmable lubrication system, which contains information on the system introduction, composition, installation, debugging, etc.


Digilube DL-5002HC Programmable Lubrication System Installation and Operational Manual - cover page
Brand
Digilube
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
53
File format
PDF
File size
1.3 MB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
8F2F8C0F3A8C4DB3B4D0A8C848952093

About this manual

The Digilube DL-5002HC Programmable Lubrication System is designed to provide pinpoint accuracy for lubricating various conveyor types, including chain pins, open trolley bearings, and roller chains. The system features a DL-5002 Head Controller (HC) with a four-line LCD screen and 16-button keypad for easy programming and adjustment. It consists of a lubricator connected to a pumping station, which can be configured with or without the optional DL-9000 Power Supply.

What's inside

  • Introduction
  • Description
  • Specifications
  • Sequence of Operations
  • Indicator Lamps
  • Installation
  • Mounting the Lubricator
  • Mounting Pumping Stations
  • Power Connections
  • Maintenance

Specifications

Head Controller Channelsfour (4) independent channels
Operating Temperature45° F minimum, 140° F maximum
Power Requirements (HC)115 VAC 3 Amps or 24 VDC 3 Amps
DL-806 Tank Capacity6 gallons
DL-812 Tank Capacity12 gallons
DL-865 Tank Capacity65 gallons
Lubricant Viscosity Range30 - 500 SSU at 100 F

Frequently asked questions

Can the DL-9000 Power Supply be used with all pumping stations?

Yes, all pumping stations (DL-806, DL-812, & DL-865) can be supplied with or without the DL-9000 Power Supply.

What types of conveyor components can this system lubricate?

The system is designed to lubricate chain pins, open trolley bearings, free carriers, swivels, cat drive chains, and roller chain.

What is the maximum operating temperature for the DL-5002HC Head Controller?

The Head Controller can operate in temperatures up to a maximum of 140° F.

How long does the pump/motor run after a lubrication cycle is completed?

After the cycle finishes, the pump/motor continues to run for approximately five minutes before shutting off.