Maxcess International GTS Load Cell User Manual

MAGPOWR GTS Load Cell User Manual, this manual introduces the use, safety instructions, installation instructions and other information of MAGPOWR GTS Load Cell


Maxcess International GTS Load Cell User Manual - cover page
Brand
Maxcess International
Document type
User Manual
Language
English
Pages
16
File format
PDF
File size
612 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
0898DE1BD40F7A10BA04787BD9CD76C5

About this manual

This user manual provides instructions for installing, maintaining, and safely operating Maxcess International's GTS Load Cell. It covers mechanical and electrical installation, safety precautions, model specifications, and adapter kits. The load cell is designed for mounting under pillow block bearings and is compatible with MAGPOWR tension readouts. Safety symbols and warnings are included to prevent injury or damage during use and maintenance.

What's inside

  • Introduction
  • Product Overview
  • Safety Instructions
  • Installation
  • Specifications
  • Service and Parts

Specifications

SeriesGTS
Connector TypeEC12
Units TypeEnglish or Metric

Frequently asked questions

What is the maximum force rating for the GTSB250-EC12M load cell?

The maximum force rating is 250 kg.

What is the maximum angle B allowed in the selection and sizing equation?

Angle B cannot exceed 45º.

What must be done if the resultant force is pulling away from the load cell?

Reverse the black (-s) and white (+s) signal leads at the terminal block of the control.