MAGPOWR GTS Load Cell User Manual, this manual introduces the use, safety instructions, installation instructions and other information of MAGPOWR GTS Load Cell
This user manual provides instructions for installing, maintaining, and safely operating Maxcess International's GTS Load Cell. It covers mechanical and electrical installation, safety precautions, model specifications, and adapter kits. The load cell is designed for mounting under pillow block bearings and is compatible with MAGPOWR tension readouts. Safety symbols and warnings are included to prevent injury or damage during use and maintenance.
| Series | GTS |
|---|---|
| Connector Type | EC12 |
| Units Type | English or Metric |
The maximum force rating is 250 kg.
Angle B cannot exceed 45º.
Reverse the black (-s) and white (+s) signal leads at the terminal block of the control.