LIGHTSKY TX1810 LED Zoom Moving Head User Manual

This user manual introduces the features and characteristics of LIGHT SKY LED TX1810 ZOOM, including general information, safety instructions, features and technical specifications, operation panel, dimension drawings, photometric data, mounting and installation, power supply and signal connection, display menu, DMX features, circuit connection diagram, troubleshooting, cleaning and maintenance, liability exemption and copyright protection.


LIGHTSKY TX1810 LED Zoom Moving Head User Manual - cover page
Brand
Light Sky
Category
lighting LED
Document type
User Manual
Language
Chinese
Pages
30
File format
PDF
File size
568 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
8FAC6F4619D97C86AFE7814BB78A006F

About this manual

The LIGHTSKY TX1810 is a professional LED moving head light featuring a zoom function, RGBW macrocolor system, and electronic strobe. It supports multiple control modes including DMX512, RDM, Stand-alone, Voice Control, and Master-Slave. The fixture includes a 1.2/4 inch TFT touchscreen display and offers various channel configurations for dimmer, shutter, color, pan, tilt, and zoom control. This manual is written in Chinese.

What's inside

  • General Information
  • Safety Instructions
  • Performance Specifications
  • Operation Panel
  • Dimensional Drawings
  • Photometric Data
  • Mounting and Installation
  • Power Supply and Signal Connection
  • Display Menu
  • DMX Traits

Specifications

Voltage100V~240V ~50/60Hz
Power246W
LED Chip10W, RGBW4in1
LED Quantity18PCS
LED Life50000H
Beam Angle7° to 55°
Color SystemRGBW macrocolor system
Strobe1-30times/second
Dimmer65536 class
Pan Speed540°/2.0 seconds
Tilt Speed180°/1.2 seconds
Control ModesDMX512, RDM, Stand-alone, VoiceControl, Master-Slave, WirelessDMX512
Display1.2/4 inches TFT touchscreen
Weight (Net)8.5KG
Weight (Gross)11.1KG

Frequently asked questions

What is the maximum ambient temperature for operation?

The fixture is intended for indoor application and should not be operated if the ambient temperature exceeds 38℃.

Can the fixture be mounted on combustible surfaces?

No, it is not permissible to install the fixture on combustible surfaces. A minimum clearance of 0.2m around cooling fans and ventilation is required.

How long should the light be used continuously?

It is suggested that continuous usage does not exceed 4 hours to avoid shortening the usage of the lamp.

What should be done before starting maintenance?

You must disconnect the power supply and let the parts cool down for at least 10 minutes before beginning maintenance.