West Mountain Radio Super PWRgate PG40S Operating Manual

Introduces the features and characteristics of West Mountain Radio Super PWRgate PG40S 2 power product. It is a high power OR gate with a built-in four-stage battery charger, suitable for ham shack


West Mountain Radio Super PWRgate PG40S Operating Manual - cover page
Brand
West Mountain Radio
Category
Other Electronics
Document type
User Manual
Language
English
Pages
11
File format
PDF
File size
426 KB
Published
18 October, 2023
Updated
18 October, 2023
MD5 checksum
46730D375C5D94C3236367A63456A6A5

About this manual

The Super PWRgate PG40S is a high-power OR gate designed to serve as a solid-state UPS for ham shacks and repeater installations. It safely transfers 40 amperes at 12 volts DC by electrically isolating the battery and power supply, preventing damage to equipment and avoiding RF interference common in traditional chargers. The unit features a built-in four-state battery charger with selectable current rates of 1, 4, 7, and 10 amperes, specifically designed for sealed lead-acid Gel and AGM batteries.

What's inside

  • Introduction
  • Features
  • Installation & Set-Up
  • Choosing a Mounting Location
  • Powerpole Connectors
  • Connecting the Battery
  • Connecting the Load
  • System Checkout
  • Super PWRgate Charger

Specifications

Current Rating40 amperes
Voltage12 volts DC
Selectable Charge Rates1, 4, 7 and 10 amperes
Voltage Drop (20A)less than 0.3 volts
Voltage Drop (40A)0.37 volts

Frequently asked questions

What battery types is the Super PWRgate PG40S designed for?

It is designed for Gel (sealed lead-acid) and AGM (sealed lead-acid, Absorbed Glass Mat) batteries.

What is the recommended voltage for charging Gel cells?

The power supply should be adjusted to 14.1V to achieve a full charge for Gel cells.

What is the recommended voltage for charging AGM cells?

The power supply should be adjusted to 14.5V to achieve a full charge for AGM cells.