1553 ADVANCED BUS INTERFACE FOR VME (ABI-V2) REFERENCE MANUAL is the reference manual of Abaco Systems / SBS ABI-V2
This manual details the setup, operation, and diagnostics of the SBS ABI-V2, a single-board MIL-STD-1553 interface for VME systems. It covers hardware installation, built-in test routines, and full-function programming including BC and RT simulation. The document includes errata and microcode initialization procedures for proper host integration.
The ABI-V2 supports real-time monitoring, double-buffered monitoring, and flexible interrupt capabilities. It requires configuration of system address, interrupt level, and vector, and can be set for short or long stub 1553 configurations. Operational specs include 5V/12V power and 0°C to 70°C operating temperature.
| Maximum Power Consumption | 5 volts at 2 amps, 12 volts at 250 milliamps |
|---|---|
| Operating Temperature | 0° to 70° Celsius, at less than or equal to 95% humidity |
| Storage Temperature | -65° to 150° Celsius, at less than or equal to 95% humidity |
| Mean Time Between Failures | 44,000 hours, based on MIL-HDBK-217F |
It is a single-board, MIL-STD-1553 interface for VMEbus systems, supporting bus controller and remote terminal simulation.
The host software must perform the startup procedure to initialize microcode, including setting CSR bit 9 to "0" for application microcode.
0°C to 70°C at less than or equal to 95% humidity.