This is a user manual for a flow meter, which mainly introduces the use method and precautions of the flow meter
This manual provides instructions for installing, operating, and maintaining a compressed air flow meter with an insertion probe. It includes safety guidelines, technical specifications, mounting procedures, electrical connections, and troubleshooting for error messages. The device is designed for use in compressed air systems up to PN16 and must be handled only by qualified personnel.
Maintenance and calibration procedures are detailed, along with steps for replacing damaged parts and handling faulty units. The manual also covers environmental disposal requirements and includes symbols for warnings and safety precautions. This manual is written in Spanish.
| Application | Compressed air systems up to PN16 |
|---|---|
| Dimensions | 44.2 mm (width), 20.5 mm (height), 4 mm (depth), 536.46 mm (length), 126 mm (height), 45 mm (width), 18 mm (depth) |
The device is designed for use in compressed air systems up to PN16.
Yes, but only by qualified personnel following the specified procedures.
Error messages include: 'Flow exceeds detection range', 'Short circuit in switch output 1°', 'Short circuit in switch output 2°', 'Short circuit in both switch outputs', and 'Sensor failure'.