Testo 745 Non-contact Voltage Tester Instruction Manual

This file is a user manual for testo 745 contactless voltage tester


Testo 745 Non-contact Voltage Tester Instruction Manual - cover page
Brand
testo
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
498 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
8031262177C6D8B5DBD8E65A6CA0EDD2

About this manual

This manual provides safety guidelines and operating instructions for the Testo 745 non-contact voltage tester. It covers how to use the device for voltage detection in the 12–1000 V range, including sensitivity settings and illumination features. Safety precautions are emphasized, especially for voltages above 120 V AC. Maintenance includes battery replacement and cleaning procedures.

Technical specifications are listed, including voltage sensitivity, frequency range, temperature tolerance, and IP67 protection. The manual also includes disposal and environmental guidelines for the device and its batteries.

What's inside

  • Instrument Overview
  • Safety Instructions
  • Intended Use
  • Operating the Instrument
  • Changing the Battery
  • Maintenance
  • Storage
  • Cleaning
  • Protecting the Environment

Specifications

Voltage IndicatorRed LED and buzzer
Sensitivities50 to 1000 V (standard setting) 12 to 50 V (high sensitivity, also displays voltages of 50 to 1000 V)
Frequency Range40 to 400 Hz
Temperature RangeOperation: -10 to 50 °C Storage: -15 to 60 °C
Relative Humidity< 80 %
Height< 2000 m
Batteries2x 1.5 V IEC LR03 (AAA)
Power ConsumptionApprox. 80 mA
DimensionsApprox. 155 x 25 x 23 mm
WeightApprox. 55 g
StandardsEN 61326-1, EN 61010-1
Protection ClassIP 67 (IEC 60529)
Warranty2 years

Frequently asked questions

What is the voltage range of the Testo 745?

The instrument detects AC voltages from 12 to 1000 V, with two sensitivity settings: 50–1000 V (standard) and 12–50 V (high sensitivity).

How do I change the batteries?

Open the battery compartment, remove the spent batteries, insert new AAA batteries according to the icon, and close the compartment.

What safety precautions should I take?

Only trained personnel should use the instrument. Avoid contact with voltages above 120 V AC, and ensure the device is not used in explosive or wet environments.

What does the red LED indicate during testing?

A slowly flashing red LED indicates the instrument is ready. Single flash means 50–1000 V range, double flash means 12–50 V range.

Download PDF (498 KB)