TaraCon Precast HollowCore Plank Design Guide

This is a design guide that illustrates how hollow precast concrete can function as a multi-purpose building system or as an integral component of a building system.


TaraCon Precast HollowCore Plank Design Guide - cover page
Brand
TaraCon Precast
Category
Other
Document type
User Manual
Language
English
Pages
25
File format
PDF
File size
702 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
2C2313861DB71FB37674E647B4936EDE

About this manual

This document serves as a design guide for TaraCon Precast HollowCore planks, illustrating how the system functions as a multi-purpose building component. It covers applications ranging from residential and hospitality to commercial and industrial structures, highlighting benefits such as cost-effectiveness, fire resistance, and structural efficiency. The guide explains that the system consists of prestressed concrete flat profile slabs with continuous hollow voids that reduce weight and cost while maintaining high load capacity.

What's inside

  • HollowCore System Uses
  • Manufacturing Process
  • Load Table Design Criteria
  • Plank Design Considerations
  • Fire Rating
  • Sound Ratings
  • Production & Erection Tolerances
  • Cross Section Details
  • Section Properties
  • Welded Connections

Specifications

Standard Width48 inches
Available Thicknesses6, 8, 10, 12 and 16 inches
Concrete Release Strength3,000 psi or 3,500 psi
Concrete 28-day Compressive Strength6,000 psi
Prestressing Strand Ultimate Strength270 ksi
Topping Strength4,000 psi
Minimum Topping Thickness2 inches

Frequently asked questions

What are the standard widths and thicknesses for HollowCore planks?

The planks are manufactured in standard widths of 48 inches and thicknesses of 6, 8, 10, 12 and 16 inches.

What is the concrete mix design strength for the planks?

The concrete mix is designed to have a release strength of 3,000 psi or 3,500 psi and a 28-day compressive strength of 6,000 psi.

What is the minimum ultimate strength of the prestressing strands used?

The uncoated, seven wire, low relaxation prestressing strands have a minimum ultimate strength of 270 ksi.

Are the load tables in this guide absolute limits?

No, the maximum spans and loads shown are not absolutes; longer spans or heavier loads may be achieved under certain conditions.