AP400 is a NEC product installation manual, which mainly introduces the installation method of the product
This guide provides step-by-step instructions for installing the NEC AP400 wireless device, including mounting against walls or ceilings, cabling requirements, and LED status indicators. It also covers regulatory compliance for different regions, including RF exposure limits and country-specific frequency bands. Safety precautions and environmental specifications are included to ensure proper installation and operation.
The document includes detailed sections on unpacking, antenna positioning, mounting the G.729 daughterboard, and troubleshooting via LED indicators. It specifies supported cable types (Cat 5/6 UTP), power requirements (PoE Class 2), and environmental conditions (operating temperature -5°C to 45°C).
| Dimensions (W x D x H) | 145 x 43 x 174 |
|---|---|
| Operating Temperature Range | -5°C to 45°C |
| IP Rating | IP66 (in outdoor box) |
| PoE Voltage | 36–57 V DC |
| PoE Class | Class 2 |
| Power Consumption | 6 Watt maximum |
| IP Network | 10/100Base-T IEEE802.3 |
| Cable Type | Cat 5 / Cat 6 UTP |
| Country/Region Support (North America) | 1920–1930 MHz (<21 dBm) |
Maximum power consumption is 6 Watts.
The operating temperature range is -5°C to 45°C.
The IP rating is IP66 when installed in an outdoor box.
North America supports 1920–1930 MHz with power less than 21 dBm.