This manual introduces the use of Atlas Copco Tools and Assembly Systems AB's Tensor DS and Tensor DL drives, including safety instructions, product introduction, interface description, installation instructions, and program instructions
This manual provides detailed instructions for operating and programming the Atlas Copco Tensor DS and Tensor DL electric nutrunner drives. It covers safety precautions, system components, installation procedures, programming using ToolsTalk DS/DL software, and troubleshooting common issues. The drives use the unique DigiTork system without torque transducers and support multi-torque settings for enhanced productivity and control.
The manual also details the differences between basic (D302/D303) and advanced (D312/D313) drive models, including features like digital inputs, relays, and rundown monitoring. It includes sections on tool compatibility, torque settings, error codes, and accessories such as I/O expanders and RE alarms.
| Drive Models | D302 / D303 (Basic) and D312 / D313 (Advanced) |
|---|
ToolsTalk DS/DL is used to program the drives. It runs on Windows 95, 98, 2000, and NT.
The DigiTork system derives torque from motor parameters like voltage, speed, temperature, and current instead of using a torque transducer.