GDS Corp GDS-IR Infrared Sensor Operation and Maintenance Manual

This manual introduces the safety information, general information, specifications, infrared detection principles, installation, calibration, operation and maintenance, troubleshooting and spare parts of the GDS-IR infrared sensor.


GDS Corp GDS-IR Infrared Sensor Operation and Maintenance Manual - cover page
Brand
GDS Corp
Category
Industrial Robot
Document type
Service Manual
Language
English
Pages
21
File format
PDF
File size
443 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
A0FCB1166FF3EF27D6FD56A2D398C83A

About this manual

This manual provides instructions for safely installing, calibrating, operating, and maintaining the GDS-IR infrared sensor. It covers safety precautions, technical specifications, installation guidelines, calibration procedures, and troubleshooting. The sensor detects various hydrocarbon gases and CO2 using infrared absorption technology and outputs a 4-20mA signal. It is designed for use in hazardous environments and requires qualified personnel for operation and servicing.

The manual includes detailed diagrams, component specifications, and maintenance tips, such as avoiding upside-down mounting, protecting from moisture, and regular calibration checks. It also lists compatible gases and temperature ranges, and provides dimensions and spare parts information for the sensor unit.

What's inside

  • Safety Information
  • General Information
  • Specifications
  • Infrared Detection Fundamentals
  • Installation
  • Calibration
  • Operation and Maintenance
  • Troubleshooting
  • Spare Parts
  • Drawings and Dimensions

Specifications

ModelGDS Corp Infrared Sensor for Combustible Gases and CO2
Power Input18 to 36V DC; power consumption less than 5 watts max.
Output4-20 mA (current source) max.1000 ohm load at 24 VDC supply voltage
Accuracy± 3% of full scale (typical) at < 50% of scale; ± 5% of full scale > 50% of scale
Response TimeT50 < 5 seconds, T90 < 10 seconds
Temperature RangeElectronics -40°C to +70°C; Extended version -40°C to +90°C
HousingJunction box epoxy-coated aluminum, sensor head 316 stainless steel
ApprovalsCSA Class 1, Division 1, Groups B, C and D Explosion Proof with flame arrestor
WarrantyFive years

Frequently asked questions

What gases does the GDS-IR sensor detect?

It detects methane, propane, ethane, ethylene, ethylene oxide, hexane, diesel, gasoline, Jet A, methanol, butane, hexane, carbon dioxide and others.

What is the response time of the sensor?

The T50 response time is less than 5 seconds and the T90 is less than 10 seconds.

How should the GDS-IR be mounted?

It should be mounted facing down or at most a 90° angle from vertical; do not mount it facing up.

What is the output signal of the sensor?

It provides a 4-20 mA current source output, compatible with 4-20mA inputs.