This is an instruction manual that introduces the features and characteristics of the OLCT 700/710 IR series infrared gas detector, including description, modular mechanical design, plug-in replaceable sensors, installation, operation, etc.
The Oldham OLCT 700 and OLCT 710 IR series are non-intrusive 'Smart' detectors designed to detect and monitor combustible hydrocarbon or CO2 gases in air. The units feature an LED display, standard analog 4-20mA output, and Modbus RS-485 outputs. A primary feature is the method of automatic calibration, which guides the user through each step via scripted instructions on the display.
| Output Signals | Analog 4-20mA and Modbus RS-485 |
|---|---|
| Sensor Technology | Non-Dispersive Infrared (NDIR) |
| Sensor Lifespan | Exceeding 5 years |
| Zero Calibration Interval | Quarterly to semi-annual |
| Span Calibration Interval | Semi-annual to annual |
The sensor is a miniature plug-in replaceable component that can be easily changed out in the field.
Unless otherwise specified, the unit is factory calibrated for methane service.
Sensors and electronics parts are guaranteed for 2 years from the date of shipment under normal conditions of use.