This manual describes the use and care of the Kenmore® Water Softener with High Flow Valve
This guide provides step-by-step instructions for installing, programming, and maintaining the Kenmore 625.383500 water softener. It includes safety guidelines, specifications, and warranty details. The unit removes hardness minerals and clear water iron from water, with performance verified by NSF/ANSI standards.
Installation requires following local plumbing codes and using a 24V transformer. The softener operates on water pressure between 20–125 psi and temperature between 40–120°F. Maintenance includes adding salt, sanitizing, and periodic checks to ensure proper function.
| Rated Softening Capacity | 12,600 @ 2.5 lbs. 26,900 @ 7.9 lbs. 32,100 @ 13.3 lbs. |
|---|---|
| Rated Efficiency | 5,040 @ 2.5 lbs. |
| Rated Service Flow Rate | 8.0 gpm |
| Water Supply Max. Hardness | 90 gpg |
| Water Supply Max. Clear Water Iron | 8 ppm |
| Water Pressure Limits | 20 - 125 psi |
| Water Temperature Limits | 40 - 120 °F |
| Amount of High Capacity Ion Exchange Resin | 0.83 cu. ft. |
Water pressure must be between 20–125 psi and temperature between 40–120°F. Do not install on hot water.
It removes hardness minerals (measured in grains per gallon) and some clear water iron (measured in parts per million).