CS Instruments FA 515 Dew Point Sensor Instruction Manual

FA 515 is an industrial dew point sensor that can measure the dew point or the pressure dew point of clean, dry and oil-free gases and compressed air.


CS Instruments FA 515 Dew Point Sensor Instruction Manual - cover page
Brand
CS Instruments
Category
Other Electronics
Document type
User Manual
Language
German
Pages
11
File format
PDF
File size
451 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
BE8A4195F13137B3A937EB4B1742903D

About this manual

The CS Instruments FA 515 is a dew point sensor designed for monitoring moisture in industrial applications such as compressed air plants, granulate dryers, and medical gases. It features a 2-wire technology with a 4...20 mA output and an RS 485 Modbus interface, offering high accuracy and long-term stability. The device is housed in an IP 66 rated zinc alloy casing and can be installed directly or indirectly in the system. This manual is written in German.

What's inside

  • Introduction
  • Notes of Safety
  • Description
  • Technical Data
  • Installation
  • Modbus Interface
  • Calibration/Adjustment
  • Warranty
  • Ordering Data

Specifications

Measuring range-80...50 °Ctd pressure dew point resp. dew point in °Ctd
Accuracytypical + 1 °Ctd von 20...-20 °Ctd
Power supply24V VDC (10..30 VDC)
Output4...20 mA 2-wire technology*™
Screw-in threadG 1/2" stainless steel
ConnectionM12, 5-pole

Frequently asked questions

What is the maximum pressure range for the standard version?

Do not exceed the pressure range > 50 bar for the standard version.

Can the 4...20 mA output and RS 485 Modbus output be used simultaneously?

No, both outputs cannot be used at the same time due to the 4...20 mA 2-wire technology (low power).

What is the default Modbus ID?

The default Modbus ID is 1.