This is smi delta force supplemental braking system's manual, including installation instructions.
This guide walks users through installing the SMI Delta Force DF0114 supplemental braking system, covering parts inventory, pedal clamp installation, tether setup, charge wire connection, and troubleshooting. It emphasizes safety and proper setup to ensure proportional braking and system reliability. The guide includes diagrams and step-by-step procedures for wiring and component placement, with warnings about cable tension and power connections.
The set screw must be tightened to 25 in. lb.
There must be at least 1/8" clearance between the actuator and the front lip of the operating unit.
The cable should allow 1/4" to 1/2" of movement in either direction.