This document is a gas water heater installation and maintenance manual, which includes the characteristics of the product and installation and maintenance methods
This manual provides comprehensive instructions for the installation, start-up, and maintenance of the Modulating Delta gas-fired combination heater. It covers pre-installation requirements, domestic and primary piping assembly, gas and electrical wiring, and system start-up procedures. The document emphasizes safety precautions regarding gas leaks, water pressure, and temperature limits to prevent injury or property damage.
| Maximum working pressure (inner tank) | 150 psig |
|---|---|
| Maximum working pressure (outer tank) | 45 psig |
| Electrical rating | 120 V, 60 Hz, less than 12 amperes |
| Maximum operating temperature (primary side) | 186º F |
| Maximum outlet temperature (domestic side) | 120º F |
| Water pH limit | 6.0 to 8.0 |
| Chloride concentration limit | Less than 80 mg/L |
Do not try to light any appliance, do not touch any electrical switch, and immediately call your gas supplier from a neighbor's phone.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
The recommended water pH level is between 6.0 and 8.0.