This manual describes the operation and precautions of CKD Parec pressure switch
This manual provides instructions for safely using and maintaining the CKD PPE pressure switch. It includes specifications, external dimensions, internal structure, handling precautions, pressure setting methods, installation guidelines, and troubleshooting. The switch is designed for air and compressed dry air, with IP65 protection and adjustable pressure settings. Proper handling and installation are critical to ensure safe operation and prevent accidents.
The manual also details model coding for ordering, including pressure range and piping connection options. It specifies that the product must not be used with corrosive or combustible gases, and warns against disassembly or improper rotation of connection areas. Maintenance and troubleshooting sections are included for ongoing use and problem resolution.
| Pressure Range | For negative pressure: 0 to 101.3kPa; For positive pressure: 0 to 100kPa; 0 to 1.0MPa |
|---|---|
| Color of Name Plate | Red, Green, Blue |
| Strain Transducer | Diffusing semi-conductor strain gage |
| Applicable Media | Air, compressed dry air |
| Proof Pressure | 0.6MPa / 0.3MPa / 1.5MPa |
| Repeatability | ±1% F.S. |
| Hysteresis | 3% F.S. or smaller |
| Temperature Characteristics | ±1% F.S. |
| Load Voltage | DC10 to 30V |
| Load Current | 5 to 50mA |
| Internal Voltage Drop | ΔV or lower |
| Current Leakage | 1mA or lower |
| Indicator Light | Yellow LED comes on at ON |
| Cable Type | Standard 3m oil-proof vinyl cable, 2-core 0.15mm² |
| Working Temperature Range | 0 to 50°C (must not be frozen) |
| Protection Rating | IP65 equivalent |
| Mechanical Vibration Proof | 10Hz to 55Hz, amplitude 1.5mm, X, Y, Z each direction, 4 hours |
| Piping Connection | R18, g6mm plug or g6mm push-in joint |
| Mass (with cable) | 3Tg (R1/8 type, plug type) / 42g (push-in joint type) |
| Mass (without cable) | 9g (R1/8 type, plug type) / 14g (push-in joint type) |
The pressure range is 0 to 101.3kPa for negative pressure, 0 to 100kPa for positive pressure, and 0 to 1.0MPa for higher pressure applications.
It is designed for air and compressed dry air. Do not use it with corrosive or combustible gases.
The protection rating is IP65 equivalent, meaning it is protected against dust and water splashes.