Electro Industries/GaugeTech FVA/FVD/FAA/FAD/FF/FT Single-Phase Digital Switchboard Monitors User's Manual

This user manual introduces the appearance, specifications, installation, wiring, operation, maintenance and troubleshooting of FVA, FVD, FAA, FAD, FF and FT models of F series single-phase digital switchboard monitors.


Electro Industries/GaugeTech FVA/FVD/FAA/FAD/FF/FT Single-Phase Digital Switchboard Monitors User's Manual - cover page
Brand
Electro Industries/GaugeTech
Category
Monitoring Equipment
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
598 KB
Published
17 October, 2023
Updated
17 October, 2023
MD5 checksum
CA71DCD48D92631EB1E4A1CEF8C407ED

About this manual

The F Series family of single-phase digital switchboard monitors is described for commercial, industrial and power generation applications. Models perform monitoring tasks including Volts Monitor, Amps Monitor, Frequency Monitor, Potential Transformer Monitor, Current Transformer Monitor, DC Shunt Readout and Transducer Readout. Options include True RMS readings for AC models with suffix -RMS and extended input voltage to 600 Volts for FF models with suffix -G.

The manual covers installation, calibration and electrical connection diagrams. The monitor fits a standard ANSI panel cutout, uses a 12-bit analog-to-digital converter, has a 4-digit readout and updates in 600ms. DC Volts and Amps accuracy is 0.05% of full scale, ±1 digit; AC Volts and Amps accuracy is 0.2% of full scale, ±1 digit.

What's inside

  • Introduction
  • Features
  • Choice of Models
  • Installation Requirements
  • Calibration
  • Switchboard Instrument Dimensions
  • Electrical Connection Diagrams for A.C. Measurements
  • Electrical Connection Diagrams for D.C. Measurements
  • Recommended Cutout for F Series

Specifications

Voltage models and full-scale rangesFVA10 (AC) 9.999V; FVA100 (AC) 99.99V; FVA600 (AC) 600.0V; FVD10 (DC) 9.999V; FVD100 (DC) 99.99V; FVD600 (DC) 600.0V
Current models and full-scale rangesFAA10 (AC) 9.999A; FAA20 (AC) 25.00A; FAD10 (DC) 9.999A; FAD20 (DC) 25.00A
Frequency monitor rangesFF60: 5.0 - 99.99 Hz; FF400: 50.0 - 999.9 Hz; FF1000: 5 - 9999 Hz
Control power115V AC, ±20%; 6VA, 47-440Hz (Suffix 115A); 230V AC, ±20%; 6VA, 47-440Hz (Suffix 230A); 24-48V DC, ±20%; 6VA (Suffix D); 125V AC/DC, ±20%; 6VA (Suffix D2)
BurdenVoltage: 0.1VA maximum; Current: 0.1VA maximum
Operating temperature-20 to +70°C
Analog-to-digital converter12-bit
DC Volts and Amps accuracy0.05% of full scale, ±1 digit
AC Volts and Amps accuracy0.2% of full scale, ±1 digit
Resolution and update rateResolution to 9999 counts; unit updates in 600ms

Frequently asked questions

Does the monitor require initial calibration?

No initial calibration is required because all switchboard instruments are calibrated at the factory.

What should I do if the monitor requires re-calibration?

Send the unit to the factory for service.

What is the product warranty period?

Electro Industries/GaugeTech warrants the product for 1 year from date of shipment.

What is the operating temperature range?

The operating temperature range is -20 to +70°C.

Download PDF (598 KB)

More Electro Industries/GaugeTech Manuals


View all Electro Industries/GaugeTech manuals →