EcoSmart™ Troubleshooting Guide is designed to help installers or homeowners troubleshoot any issues experienced during the lifetime of the tankless water heater.
This document serves as a troubleshooting guide for EcoSmart ECO 18 through 36 kW electric tankless water heater models. It is designed to assist both qualified installers and homeowners in diagnosing common operational issues encountered during the unit's lifetime.
The guide provides step-by-step procedures for resolving specific problems, such as LED display activation failures, lack of heating output, power supply issues, and error codes related to thermistors, flow meters, electrical connections, fuses, and high temperatures. It includes instructions on how to test components like thermistors and flow meters, verify electrical wiring configurations, and replace inline fuses.
You should flush the system with high volume water to clear debris from the propeller, then clean the impeller by removing the cover and rinsing it out.
The inline fuse designed to protect the control board against power surges must be a 250 Volt, 3 Amp fuse.