This manual introduces the features and installation instructions of SafePass JT Safety Light Curtain.
The document covers the installation procedure for the SafePass JT safety light curtain, including removing covers, drilling holes, aligning the transmitter and receiver units, and securing them with screws. It details the connection of power supplies and signal wires to ensure proper operation.
Technical specifications are provided for various models (JT10 and JT20), covering detection distances, operating voltages, response times, and environmental ratings. The manual also includes wiring diagrams, product dimensions, application layouts, and a troubleshooting guide for common LED indicator statuses.
| Height Detection Distance (JT10) | 1000mm |
|---|---|
| Height Detection Distance (JT20) | 2000mm |
| Response Time Options | 50/100/150/200ms adjustable |
| Working Temperature Range | -10~60 °C |
Adjust VR1 clockwise to increase strength and counter-clockwise to decrease it.
Blocking one beam triggers in 2 seconds, while blocking two or more adjacent beams triggers immediately.
A warning status occurs when the green LED is on but the red light goes out with no sound prompt.