This document describes detailed information about the boiler system in the KLM Technology Group Operating Manuals.
This manual covers the operation of two utility boilers designed to supply 125,000 lbs/hr each of superheated steam to maintain the Super High Pressure Steam Header at 1500 psig. These systems are primarily used during startup when insufficient steam is being produced or to supply additional steam during imbalances in the steam header.
| Boiler Steam Output per Unit | 125,000 lbs/hr |
|---|---|
| Super High Pressure Steam Header Pressure | 1500 psig |
| Deaerator Design Pressure | 10 PSIG |
| Deaerator Design Temperature | 250 degrees F |
| Boiler Feed Water Pump High Header Pressure | 1500 psig |
| Boiler Feed Water Pump Medium Header Pressure | 950 psig |
| Amine Dosing Pump Discharge Pressure | 70 PSIG |
| O2 Scavenger Dosing Pump Discharge Pressure | 70 PSIG |
| Phosphate Dosing Pump Discharge Pressure | 2000 PSIG |
They are primarily used during startup when insufficient steam is being produced to provide additional steam makeup to the 1500 psig steam header.
The greatest hazard is the potential for 'fuel related' explosions.
Two utility boilers are designed to supply superheated steam.