This document is the user manual of Z-LINK respirator
The RPB Z-LINK is a multi-use respirator approved by NIOSH for use with the RPB PX4 AIR Powered Air Purifying Respirator. It is designed to protect the operator's face and head against sparks and hazardous ultraviolet and infrared rays emitted during welding, grinding, and other industrial applications. The device meets ANSI Z89.1 for head protection and ANSI Z87+ for eye and face protection.
| NIOSH Category | Powered Air Purifying Respirator |
|---|---|
| Head Protection Standard | ANSI Z89.1 |
| Eye and Face Protection Standard | ANSI Z87+ |
| Operating Temperature Range | 14°F to 140°F (-10°C to +60°C) |
| Compatible Air Source | RPB PX4 AIR Powered Air Purifying Respirator |
The respirator should only be used within the temperature range of 14°F to 140°F (-10°C to +60°C).
No, the Z-LINK is only approved to be used with the RPB PX4 AIR PAPR.
No, the respirator does not provide hearing protection, and earplugs or earmuffs must be fitted when noise levels exceed OSHA limits.