About this manual

This manual covers the Fiamma Elektra Compact C 016 series electric wall boilers, available in 12 kW, 18 kW, and 24 kW models. The appliance is designed for heating and sanitary hot water production, complying with EC Directive 2006/95/EC and relevant IEC/EN standards. Key features include noiseless functioning, high reliability, and a D.E.S. system that manages temperature probes to ensure comfort and economy by reducing power consumption when not at maximum capacity.

What's inside

  • Presentation
  • Warnings
  • Dimensions
  • Hydraulic connections
  • Main technical features
  • Positioning the boiler
  • Control panel
  • Keyboard panel
  • Turning on the boiler
  • Display of malfunctions

Specifications

Maximum electrical output12 kW, 18 kW, or 24 kW
Electrical supplySingle-phase 230-240 V - 50 Hz
Maximum pump head7 m.c.a.
Expansion vessel capacity10 liters
Maximum heating operating pressure0,25 MPa (2,5 bar)
Maximum sanitary operating pressure0,55 MPa (5,5 bar)
Maximum thermal safety limit100°C

Frequently asked questions

How do you switch between Winter and Summer operation modes?

Press the MODE key (J4) repeatedly for at least 5 seconds to switch between WINTER and SUMMER modes.

What does the 'Err' code with 'F 009' indicate?

It indicates a Hardware EEPROM failure.

What is the optimum pressure range for the heating system?

The optimum pressure for the system is between 1 and 1,5 bar.