Coleman Mach Series Rooftop Air Conditioner Service Manual

This is a service manual that guides Coleman Mach series rooftop air conditioner's repair, the air conditioner is equipped with a remote wall thermostat control system.


Coleman Mach Series Rooftop Air Conditioner Service Manual - cover page
Brand
Coleman
Category
Air conditioner
Document type
Service Manual
Language
English
Pages
18
File format
PDF
File size
786 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
CF56394B52052F3C598448D6C6D7D55D

About this manual

This document serves as a guide for qualified technicians to diagnose issues within the Coleman Mach series rooftop air conditioning system. It focuses specifically on units utilizing a remote wall thermostat control setup, detailing the electrical interactions between the thermostat and the ceiling assembly components.

The manual covers the fundamental operation of 12VDC thermostats and their connection to either individual relays or Printed Circuit Boards (PCBs) located in the ceiling plenum. It provides specific instructions on checking ceiling plenums with various relay configurations, verifying thermostat operations, and testing PCB functionality without removing the control box lid.

What's inside

  • Introduction to Wall Thermostats
  • Thermostat Operations and Wiring
  • Thermostat Location Considerations
  • Introduction to Relays
  • Checking Ceiling Plenums with Individual Relays
  • Checking Ceiling Plenums with Printed Circuit Boards
  • Diagnostic Flow Charts
  • Wiring Diagrams

Specifications

Control Voltage12 VDC
Thermostat TypeCombination (Heat / Cool)

Frequently asked questions

What safety precautions must be taken before servicing the unit?

Always disconnect the power supply to the appliance before doing any work. This involves switching breakers off, disconnecting external connections, and removing battery cables.

Can the different Coleman wall thermostats be interchanged?

Yes, all three types of thermostats listed (Mechanical/By-Metal, Electronic, and Electronic Digital Display) are completely interchangeable.

How does the thermostat signal the compressor to run?

When cooling is selected, 12VDC travels from the thermostat red wire to the yellow (Y) wire and then energizes the relay coil to close the contacts.