This is a service manual that guides Coleman Mach series rooftop air conditioner's repair, the air conditioner is equipped with a remote wall thermostat control system.
This document serves as a guide for qualified technicians to diagnose issues within the Coleman Mach series rooftop air conditioning system. It focuses specifically on units utilizing a remote wall thermostat control setup, detailing the electrical interactions between the thermostat and the ceiling assembly components.
The manual covers the fundamental operation of 12VDC thermostats and their connection to either individual relays or Printed Circuit Boards (PCBs) located in the ceiling plenum. It provides specific instructions on checking ceiling plenums with various relay configurations, verifying thermostat operations, and testing PCB functionality without removing the control box lid.
| Control Voltage | 12 VDC |
|---|---|
| Thermostat Type | Combination (Heat / Cool) |
Always disconnect the power supply to the appliance before doing any work. This involves switching breakers off, disconnecting external connections, and removing battery cables.
Yes, all three types of thermostats listed (Mechanical/By-Metal, Electronic, and Electronic Digital Display) are completely interchangeable.
When cooling is selected, 12VDC travels from the thermostat red wire to the yellow (Y) wire and then energizes the relay coil to close the contacts.