Instructions and parts manual for Platinum® series vacuum pumps
This document serves as the operating instructions and parts manual for the JB Industries TMPLATINUM Series 2-stage, direct drive vacuum pumps. It provides essential information on pump specifications, including CFM ratings and voltage options for various models. The guide details proper startup and shutdown procedures to prevent oil ingestion and outlines specific maintenance requirements, such as oil changes and flushing contaminated systems.
| Vacuum Performance | 15 micron or better |
|---|---|
| Operating Temperature | 30°F minimum |
| Normal Operating Temperature | approximately 160°F |
| Oil Capacity (DV-42N) | 26 oz (798 cc) |
| Oil Capacity (DV-285N) | 26 oz (798 cc) |
| Warranty Period | 2 years |
Use oil specifically refined for deep vacuum pumps, such as BLACK GOLD Pump Oil.
Pump oil should be changed after each use, or several times if the system is heavily contaminated.
No, the unit has been drained of oil for shipment and must not be operated without adding oil.
The pump is warranted against defects in materials and workmanship for 2 years.