Metal tube float (rotor) flow meter user manual, introduces the selection, installation, and use of flow meters
The document provides a user guide for the LZ series intelligent metal tube float (rotor) flow meters. It details the instrument's structure, working principle based on variable area measurement, and its application in measuring gas and liquid flows under various conditions.
Key features include a robust all-metal design, compatibility with hazardous environments (Exia/Exd), and optional HART communication capabilities. The manual outlines technical specifications such as flow ranges for water and air, accuracy levels, material options (stainless steel, titanium, etc.), and installation dimensions. This manual is written in Chinese.
| Measurement Range (Water 20°C) | 16~150000 l/h |
|---|---|
| Measurement Range (Air 0.1013MPa 20°C) | 0.5~4000 m3/h |
| Range Ratio | 10:1 (Special type 20:1) |
| Accuracy Grade | 2.5 (Special type 1.5% or 1.0%) |
| Working Pressure (DN15~DN50) | PN16MPa |
| Medium Temperature (Standard Type) | -80℃~+220℃ |
| Power Supply (Standard) | 24VDC±20% |
The sensor contact materials include stainless steel, Hastelloy, titanium, and stainless steel lined with FEP.
The accuracy grade for the standard type is 2.5.
Yes, the transmitter can be equipped with HART communication functionality.