About this manual

This manual covers the installation, unpacking, and startup procedures for the Domnick Hunter PNEUDRI range of compressed air dryers. These units utilize Pressure Swing Adsorption (PSA) technology with desiccant material to achieve dewpoints of -40°C or optionally -70°C. The document provides specific guidance on mounting orientation, electrical connections, and required filtration.

What's inside

  • General Description
  • Safety Warning
  • Technical Specification
  • Unpacking
  • Installation
  • Start Up Procedure
  • Shutdown Procedure
  • Maintenance Recommendations
  • Fault Diagnosis

Specifications

Operating Flow Range3 scfm - 13 scfm (2L/s - 6 L/s)
Dewpoint Nominal-40 oC (-40oF)
Optional Dewpoint-70 oC (-94oF)
Maximum Operating Pressure10.5 bar g (150 psi g)
Standard Electrical Supply240V AC / 1PH / 50Hz
Noise Level75 db(A)

Frequently asked questions

What is the regeneration process for this dryer?

The dryer uses Pressure Swing Adsorption (PSA) where a small percentage of dried air regenerates the saturated chamber by expanding to atmospheric pressure.

How often does the changeover occur?

The adsorption and desorption chambers are automatically reversed approximately every 2 minutes.