About this manual

The Voith BTM is a monitoring system designed for Voith turbo couplings of sizes 366 up to 1330. It measures the operating medium temperature directly in the medium using a non-contacting signal transmission method. This allows for the quick identification of stress changes and the prevention of excess temperatures, thereby avoiding downtime caused by fusible plug loss. The system consists of a temperature sensor, a blind screw for balancing, a stationary aerial, and an electronic evaluator.

What's inside

  • Possible Applications
  • BTM Functioning
  • Technical Data
  • User Information
  • Safety
  • Installation
  • Display and Setting of Evaluator
  • Commissioning
  • Maintenance, Servicing
  • Malfunctions - Remedial Actions

Specifications

Measuring range0 °C to 180 °C
Operating medium temperature max.200 °C
Measuring tolerance± 2 K
Permissible ambient temperature-40 °C … 100 °C
Protection classIP 67
Cable length25 m

Frequently asked questions

What is the intended use of the BTM?

The BTM is a monitoring system for Voith turbo couplings used to measure the operating medium temperature.

Can fusible plugs be replaced by blind screws?

No, it is not allowed to replace fusible plugs by blind screws or plugs with different nominal response temperatures when the BTM is used.

What happens if a fusible plug responds?

The turbo coupling will be damaged if operation is continued after a fusible plug responded.