Pentair Fleck SoftPlus SP-5800SXT Series Water Softener Owner's Manual & Installation Guide

This is a manual that introduces the use of soft water treatment system, including installation, startup and operation


Pentair Fleck SoftPlus SP-5800SXT Series Water Softener Owner's Manual & Installation Guide - cover page
Brand
Pentair Fleck
Category
Other
Document type
User Manual
Language
English
Pages
38
File format
PDF
File size
619 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
91F895C2C9D5F6519CBA7DF2A729F271

About this manual

The document serves as an owner's and installer's guide for the SoftPlus™ Series High Efficiency Water Softeners. It details the setup of the system which utilizes a Fleck 5800SXT control valve to manage water treatment cycles automatically.

Key sections cover general warnings, operating conditions such as pressure and temperature limits, and a comprehensive step-by-step installation process including plumbing connections and electrical grounding. The guide also explains how to program the controller, add salt, perform maintenance, and troubleshoot common issues.

What's inside

  • General Warnings
  • Operating Conditions
  • Pre-Installation Inspection
  • Selecting an Installation Location
  • Prepare Treatment Tank
  • Install Inlet and Outlet Plumbing Connection
  • Drain Line Installation
  • Control Valve Set-up
  • Initial Start-up and Leak Testing
  • Regeneration

Specifications

Minimum Water Pressure20 PSI
Maximum Water Pressure90 PSI*
Recommended Water Pressure40-70 PSI
Water Temperature Range36F to 100F (2 to 38C)
Air Temperature Range32F to 125F (0 to 52C)
pH Range5.0 to 9.0

Frequently asked questions

Can I install this water softener outdoors?

Exterior installation is possible in warm climates, but interior installation is strongly recommended because the system cannot be allowed to freeze.

Where should I install the water softener relative to other fixtures?

The system should generally be located after your water pump and pressure tank, before your hot water heater, and close to the main incoming water line.

What is the recommended maximum hardness for this system?

The maximum recommended hardness is 75 grains per gallon (770 mg/l).

Download PDF (619 KB)