This is a manual that introduces the use of soft water treatment system, including installation, startup and operation
The document serves as an owner's and installer's guide for the SoftPlus™ Series High Efficiency Water Softeners. It details the setup of the system which utilizes a Fleck 5800SXT control valve to manage water treatment cycles automatically.
Key sections cover general warnings, operating conditions such as pressure and temperature limits, and a comprehensive step-by-step installation process including plumbing connections and electrical grounding. The guide also explains how to program the controller, add salt, perform maintenance, and troubleshoot common issues.
| Minimum Water Pressure | 20 PSI |
|---|---|
| Maximum Water Pressure | 90 PSI* |
| Recommended Water Pressure | 40-70 PSI |
| Water Temperature Range | 36F to 100F (2 to 38C) |
| Air Temperature Range | 32F to 125F (0 to 52C) |
| pH Range | 5.0 to 9.0 |
Exterior installation is possible in warm climates, but interior installation is strongly recommended because the system cannot be allowed to freeze.
The system should generally be located after your water pump and pressure tank, before your hot water heater, and close to the main incoming water line.
The maximum recommended hardness is 75 grains per gallon (770 mg/l).