Instructions in the manual describe how to replace the display console and accessory tray and the display console support assembly for Life Fitness Models X9i, 8500, 9100, and 9500HR Cross-Trainers
This document serves as a service and repair guide for Life Fitness Models X9i, 8500, 9100, and 9500HR Cross-Trainers. It provides detailed, step-by-step instructions for technicians on how to replace various components, including the display console, console support assembly, rear covers, crankarm roller assembly, crankarm assembly, drive belt, alternator, and power control board.
| Drive Belt Tension (New) | 170 lbs |
|---|---|
| Drive Belt Tension (Used) | 160 lbs |
| Alternator Belt Tension (New) | 75-85 lbs |
| Alternator Belt Tension (Used) | 60 lbs |
| Crankarm Cover Torque | 28-33 in lbs |
| Arm Extension Torque | 30-35 ft lbs |
| Alternator Mounting Bolt Torque | 18-20 ft lbs |
| Alternator Pivot Bolt Torque | 50-60 ft lbs |
| PCB Mounting Bracket Torque | 33-37 in lbs |
| Pedal Clamp Pressure | 30-40 psi |
A Phillips screwdriver is required to remove the mounting screws and disconnect the connectors.
A maximum of .005" clearance must be maintained between the roller bearing and the collar.
The pedal lever nuts should be tightened to a torque of 30-35 ft. LBS.
The reed switch is located on the back side of the PCB bracket.