This document is the operation manual of 242 DC Isolator Unit
The Eberle Design Model 242 is a dual channel DC Isolator unit designed to meet Caltrans specifications. It features optically isolated solid-state transistor outputs and individual front panel controls for testing operational modes, indicated by high-intensity LEDs.
Installation involves plugging the keyed edge connector into an appropriate slot of a standard input file cabinet. The unit requires no adjustments or preventive maintenance but includes a specific troubleshooting sequence for diagnosing power supply faults or channel detection issues.
| Operating Voltage Range | 80 to 135 Vac nominal |
|---|---|
| DC Input True Threshold | less than 8 Vdc |
| DC Input False Threshold | greater than 12 Vdc |
| Output Current Maximum | 50 mA |
| Collector Voltage Maximum | 50 Vdc |
| Input Pulse Width Accept | greater than 25 ms |
No, the unit requires no adjustments or preventive maintenance.
The unit operates at voltages as low as 80 Vac, though it requires a nominal 115 Vac supply.