This is a STS SCA Data Specifications v4.20.2 Data Collection Form fields description document
This document serves as the primary reference for data managers abstracting clinical data into the STS National Database (Adult Cardiac). It provides detailed definitions for data collection form fields and clarifies the intent behind specific entries to ensure consistency across all participating sites.
The guide covers essential administrative procedures, including how to handle procedure inclusion criteria, managing multiple admissions within an episode of care, and the correct coding for 'No', 'Unknown', and 'Not Documented' scenarios. It also outlines policies regarding data importation from external sources like Electronic Medical Records (EMR) and Unique Device Identification (UDI) numbers.
A new DCF is required if the patient has a separate readmission requiring an ACSD procedure within 30 days of the first procedure, such as returning for a valve repair after a CABG.
'No' is used if there is no mention of a condition in the documentation (e.g., no mention of cancer), while 'Unknown' is used when clinical documentation exists but the specific value is missing or the patient cannot give history.
STS does not want data managers to manually enter Device UDI numbers; they should use barcode scanning or copy-paste methods if available.