Schluter DITRA-HEAT Installation Guide

The document is the Schluter®-DITRA-HEAT Installation Guide, which introduces how to install wood joist, uncoupling membrane and heating cables etc.


Schluter DITRA-HEAT Installation Guide - cover page
Brand
Schluter
Category
Other
Document type
Installation Guide
Language
English
Pages
20
File format
PDF
File size
662 KB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
FFE56ABC7676F220598D4F4EDDB4B813

About this manual

This guide provides installation instructions for the Schluter DITRA-HEAT uncoupling membrane system equipped with heating cables. It is designed for use over wood subfloors in interior dry or wet areas, ensuring compatibility with ceramic, porcelain, and natural stone tiles. The document outlines specific requirements for subfloor preparation, including joist spacing and minimum thicknesses for single or double-layer wood constructions.

Key installation steps include the proper placement of movement joints, which are required in addition to the membrane, and the selection of appropriate setting and grouting materials compliant with ANSI standards. The guide also details limitations regarding tile sizes and specific considerations for natural stone and moisture-sensitive materials.

What's inside

  • Areas of Application
  • Movement Joints
  • Substrate Preparation
  • Setting and Grouting Materials
  • Heating Cables
  • Testing & Certifications
  • Warranty
  • 208 V Applications

Specifications

Maximum joist spacing (single layer)16" (406 mm) o.c.
Maximum joist spacing (double layer)24" (670 mm) o.c.
Minimum subfloor thickness (single layer)19/32" (76 mm)
Minimum subfloor thickness (double layer)23/32" (79 mm)
Minimum tile size (natural stone)2" x 2" (50 mm x 50 mm)
Required setting mortarUnmodified thin-set mortar - ANSI A118.1

Frequently asked questions

Does DITRA-HEAT eliminate the need for movement joints?

No, movement joints including perimeter joints must still be installed in accordance with industry standards.

What is the maximum allowable spacing for joists, I-joists, or floor trusses when using a single layer of OSB or plywood subfloor?

The maximum spacing is 16 inches on center for a single layer subfloor, or 19.2 inches on center for a single layer subfloor with specific requirements.

What is the minimum required thickness for a tongue-and-groove subfloor when using a single layer of OSB or plywood?

The minimum subfloor thickness must be 19/32 inch or 5/8 inch nominal.

What type of mortar must be used to seal seams and floor/wall transitions where a waterproof floor is required?

Seams and transitions must be sealed using unmodified thin-set mortar.